For 16-inch joist centers, subfloor plywood thickness commonly starts around 19/32 inch in rated floor systems; wider spacing calls for an approved higher-capacity assembly. Choosing the wrong panel can cause deflection, rework and rejected shipments. HCPLY helps importers specify panel dimensions, core construction and glue while keeping structural approval tied to the required test evidence.
What sizes and thicknesses can each factory line build?
HCPLY makes plywood from 3–40 mm thick, with common orders at 3, 5, 9, 12, 15, 18, 21 and 25 mm. For a subfloor enquiry, the first distinction is the proposed panel build versus a structural panel approved for the floor design. The latter needs the appropriate performance evidence.

| Producing line | Core and surface | Relevant thickness examples | Thickness tolerance | Intended purchasing decision |
|---|---|---|---|---|
| Our furniture line | Full-stitched styrax or eucalyptus core; sanded veneer face | 12, 15, 18, 21, 25 mm | ±0.2 or ±0.3 mm as ordered | Smooth, controlled-caliper layers or interior floor components |
| Our commercial and packing line | Acacia core; raw or light-sanded face | 12, 15, 18, 21, 25 mm | ±0.5 mm; packing ±0.5–1.0 mm | Industrial floor and packing-panel enquiries |
| Our construction line | Acacia or eucalyptus core; phenolic or melamine film, including anti-slip | 12, 15, 18, 21, 25 mm | ±0.5 mm | Temporary platform or protected industrial-surface enquiries |
Standard sheet sizes include 1220×2440, 1250×2500, 1220×2135, 1220×1830, 915×2440, 915×2135 and 915×1830 mm. Length and width tolerance is ±2 mm; custom cutting is available. A square-edge dimension is a purchasing measurement, not a tongue-and-groove profile or a span rating.
The distinction between subfloor plywood grades and thickness is worth keeping in the purchase specification: a thicker ungraded sheet cannot inherit a structural classification.
How does subfloor thickness relate to joist spacing?
Subfloor thickness is selected against joist spacing, structural panel rating, edge support, load and finished-floor assembly. At 16-inch centers, a commonly specified rated panel is 19/32–23/32 inch; at 24-inch centers, 23/32 inch or thicker is common. Those figures describe rated systems, not automatic approval of an HCPLY sheet.
| Joist spacing, center to center | Reference rated-panel selection | What the importer must check |
|---|---|---|
| 16 in (406 mm) | 19/32 in (about 15 mm) or 23/32 in (about 18 mm) | Floor span designation, edge support and finish requirements |
| 19.2 in (488 mm) | 23/32 in (about 18 mm) frequently specified | Rated performance at the actual spacing |
| 24 in (610 mm) | 23/32 in (about 18 mm) or 7/8 in (about 22 mm) | Load, edge detail and any additional underlayment |
| 32 in (813 mm) | Engineered, higher-rated floor assembly | Project-specific structural design |
Washington State’s 2021 archived WAC 246-359-220 specifies grade-stamped structural panels and distinguishes 16-inch from 24-inch joist spacing for its regulated construction category. Its requirements are jurisdiction- and application-specific, rather than a universal international purchasing standard. Washington State floor-framing rule.
For a structural application, request a test report the buyer accepts for the proposed panel and assembly. HCPLY does not place an APA or PS 1 stamp on its panels. The engineer or approving authority determines whether the documented build meets the project’s structural requirements.
What size plywood should a subfloor order specify?
A subfloor order should state nominal thickness in millimeters, sheet length and width, tolerance, core construction, glue system and edge profile. Record joist spacing separately so the structural reviewer can match the panel evidence to the floor design.
The common 1220×2440 mm sheet is close to a nominal 4×8 ft format, but the dimensions are not identical. A buyer working from imperial drawings should reconcile panel coverage, perimeter gaps and cutting yield before the purchase order is signed.
The specification should also say whether panels form a single structural layer, a second underlayment layer or a removable industrial deck. These are different load paths and finish interfaces. See subfloor layer arrangements for the distinction between layers and their functions.
Can 1/2-inch plywood be used for a subfloor?
A nominal 1/2-inch sheet is about 12.7 mm, but thickness alone does not establish structural suitability. A 12 mm panel should not be substituted for a rated structural subfloor merely because the dimensions appear close.
Some engineered floor assemblies use thin plywood as a supplementary layer above an approved structural deck. In that case, the first layer carries the specified span and the second addresses the finish assembly. The buyer should distinguish that application from a single unsupported subfloor sheet.
For square-edge stock, unsupported longitudinal joints can require blocking; tongue-and-groove joints provide a different edge-support arrangement. The architect’s fastening and edge-support detail remains part of the specification, alongside the sheet thickness.
How thick are floor joists, and what does that change?
Floor joist depth and width are framing dimensions, while joist spacing is the distance between adjacent joist centerlines. A joist described as 2×8 does not mean the supports are eight inches apart.
Joist species, grade, span, loading and spacing determine the framing design. Panel thickness addresses bending between supports, while the joists themselves carry loads toward beams and walls. Both components must satisfy the approved floor system.
The archived Washington State rule gives a specific example: minimum two-by-six joists at 16-inch centers or two-by-eight at 24-inch centers, within its stated span and material conditions. Those figures should not be carried into an unrelated warehouse or export-market design without engineering review.
Which line should press the requested floor panel?
Our commercial and packing line is the starting point for a raw acacia-core industrial floor enquiry. Our furniture line makes a full-stitched, sanded panel where caliper and a smoother surface drive the specification. Our construction line makes film-faced panels for construction and temporary working surfaces.
The difference matters even when every order says 18 mm. The commercial build has an unsanded or lightly sanded face and ±0.5 mm tolerance. The furniture build has a sanded face and an ordered ±0.2 or ±0.3 mm tolerance. The construction build uses film over an unsanded acacia or eucalyptus core.
For exposure planning, specify glue separately from emission class. Melamine glue is the MR system with a 12-hour boil designation; phenolic glue is the WBP system with a 72-hour boil designation. E0, E1 and E2 describe emission classes, rather than glue recipes. Exterior plywood specifications address the weather-exposure purchasing question.
What about CDX, OSB and moisture exposure?
CDX is a North American sheathing designation associated with face grades and exposure classification. It should be purchased against the specified structural rating, rather than treated as an interchangeable synonym for any raw plywood. Read CDX subfloor suitability for that separate grade decision.
Oriented strand board (OSB) is another structural panel category; we do not press OSB. Its rated products can be designed for subfloors, but the comparison must use equivalent structural ratings, exposure classes and installation conditions.
Wet construction conditions call for an appropriate bond system, edge treatment and a floor assembly that drains or dries as designed. A water-resistant glue bond does not turn the entire floor into a waterproof system. For tile and stone, the finish manufacturer and engineer must specify deflection limits, underlayment and waterproofing details.
What size plywood works for a shed floor or industrial platform?
A shed-floor sheet size should follow support spacing, intended loads, exposure and the cutting layout. For industrial buyers, 1220×2440 mm stock simplifies a repeated panel schedule, while smaller formats can reduce on-site cutting for narrow decks.
An outdoor shed, container floor or temporary platform can carry concentrated equipment loads that differ from residential live loads. Ask for the maximum point load, wheel contact area, support geometry and whether the deck remains exposed to rain.
Film-faced construction plywood is a distinct surface option, with standard 120 g/m² film, premium 135 g/m² film or 220 g/m² anti-slip film. Those are surface weights, not structural span ratings. The project designer should determine whether a tested assembly meets the intended industrial load.
How much does an 18 mm sheet weigh and ship?
An 18 mm, 1220×2440 mm sheet weighs 26.79 kg with styrax core, 31.08 kg with acacia core or 34.83 kg with eucalyptus core, before film weight. Core density drives the difference: 500, 580 and 650 kg/m³ respectively.

| 18 mm core | Sheets per pallet | Full 40HC sheets | Volume | Panel mass |
|---|---|---|---|---|
| Styrax | 55 | 990 | 53.05 m³ | 26.52 t |
| Acacia | 55 | 880 | 47.15 m³ | 27.35 t |
| Eucalyptus | 53 | 795 | 42.60 m³ | 27.69 t |
The 40HC payload ceiling is 28.5 t. A mixed specification container can combine compatible plywood builds while staying within that ceiling. Use the container-load calculation for the packing-specific decision and comparison across factory lines for the product mix.


What can an inspector check at the producing factory?
An inspector can witness caliper readings, sheet dimensions, core construction and surface condition against the signed purchase specification. HCPLY coordinates the inspection at the producing factory, where the goods are pressed and packed.

A practical witness sequence is:
- Identify the order lot and the agreed core, face and glue fields.
- Measure thickness at the agreed sampling points and record actual readings against the ordered tolerance.
- Check sheet length, width, visible gaps and edge condition; inspect representative cut sections for ply construction.
- Match the packed pallet labels and quantities to the packing list before loading.
- Review the applicable laboratory report against the buyer’s structural performance requirement when the application calls for one.
At 18 mm, the typical veneer build contains 11–13 plies, with core veneer thickness around 1.4–2.0 mm. Ply count alone cannot replace bending, bond or structural qualification tests.
Which documents travel with the shipment?
The packing list records the shipped panel specification and quantities; the commercial invoice and bill of lading identify the commercial shipment. The certificate of origin and applicable phytosanitary and fumigation papers accompany the export documentation.
For EU lots, the origin documentation can include EUR.1 and the EUTR/EUDR file set. CIF shipments include insurance documents; order-specific files can include agreed emission certificates, test reports and FSC claims on sales documents. Member-factory FSC, CARB P2, ISO 9001 and CE certificates are shown with factory details masked, on request.
After loading, the draft shipping documents come to you for approval. For related purchasing structures, see several plywood types under one export arrangement.
How should an importer request a trial container?
A useful enquiry names the destination, floor assembly and performance evidence required before asking for a production quotation. The project engineer should approve the structural panel specification independently of commercial negotiations.
For orders with no listed starting price, thickness, core construction, glue system, face treatment, cutting and test requirements drive the quotation. A full-stitched sanded build costs more to produce than a basic loose-laid raw build because it needs additional veneer preparation and finishing. Request a written quotation against the final build rather than applying a generic price per sheet.
The minimum order is one 40HC, with specifications mixed within the payload limit. Factory lead time runs 15–45 days from receipt of the 30% deposit; the exact figure depends on order size, line loading and what the contract fixes. The remaining 70% is paid on the scan of the bill of lading, by T/T, or by irrevocable sight L/C. We ship FOB Hai Phong, or CFR (CNF) or CIF to your port. Samples cost nothing: a first-time buyer pays the courier, and that charge comes off the first confirmed order.
Send Lucy at export@vietnam-plywood.com the specification below through contact:
Application: industrial subfloor / shed floor / secondary floor layer
Line or core: commercial and packing / acacia (or specify alternative)
Glue: MR melamine / WBP phenolic, as required
Emission: E0 / E1 / E2, as required
Face and grade: matt raw / specified veneer and A/B grade
Thickness and tolerance: 18 mm, +/-0.5 mm (example)
Size: 1220 x 2440 mm (example)
Quantity: one 40HC, mixed specification if required
Destination port: [port and country]
Joist spacing, loads and structural test report required: [details]
Next step: plan a trial container against the approved panel and floor-assembly specification.